KNG199ICW error codes and safe responses

Model-specific fault labels, reset limits and qualified-service guidance for KNG199ICW.

Covered models: KNG199ICW

Safety comes first

If you smell gas, do not try to light an appliance, touch electrical switches or use a phone in the building. Call your gas supplier from a neighbor’s phone and follow their instructions. If the supplier cannot be reached, call the fire department. Installation and service belong to a qualified installer, service agency or gas supplier.

Source: ICW manual: Important Safety Information

E5 or C4: special blocked-vent warning

For E5 or C4, the manual instructs you to CLOSE the gas valve at the manual shut-off point, then check vent terminations for obstructions. If none are found, it says to press POWER to reset. If the code persists, call a qualified service technician or the gas supplier. Do not repeatedly reset, dismantle venting or improvise a gas-reopening sequence; get qualified help when the next step is unclear.

Source: ICW manual: Error Codes and Solutions

Minor issues are not all faults

For minor problems, the manual describes pressing POWER on the front panel, or turning the faucet off and back on. It gives no five-minute waiting interval for this model. This does not override the gas-odor instructions or the E5/C4 warning.

Source: ICW manual: Error Codes and Solutions

Model-specific error reference

CodeManual labelHomeowner response / service boundary
E0E0 DisplayedOutlet sensor fault: qualified service required.
E1Accidental Flame LostQualified service required; no gas-pressure adjustment or valve repair by the homeowner.
E2Flame Signal Detected Before IgnitionQualified service required. Do not perform the live electrical diagnostic in the manual.
E3*Thermistor Open CircuitStop use and arrange qualified service for overheating or a thermistor fault.
E4Outlet Water Temperature Exceeds 185°F (85°C) For Over 3 SecondsStop use and arrange qualified service.
E5Fan FailureFollow the special E5/C4 warning above; qualified service required.
E6Gas Valve FailureQualified service required.
EEOvertimeThe table describes more than 40 minutes of continuous burner operation. It directs closing and reopening the faucet. Seek service if the problem persists.
F2Inlet Water Temperature Sensor FailureQualified service required.
C0Ignition FailureQualified service required. Do not bleed gas lines or repeatedly attempt ignition.
C1Residual FlameQualified service required; the table identifies gas-valve leakage.
C4Vent BlockageFollow the special E5/C4 warning above; no internal vent repair.
C9Exhaust Gas Temperature Sensor FailureQualified service required.
CAExhaust Gas Temperature Too HighStop use and arrange qualified service.
CFHeat Exchanger Outlet Temperature Sensor FailureQualified service required.

Source: ICW manual: Error Codes and Solutions

Service-only entries and label differences

The manual also lists E9 (Water Valve Failure), CB (Bypass Water Valve Failure) and controller faults A0–A5. E9 and CB are marked as not displayed in its Appliance Servicing inventory. Do not enter service mode to diagnose them. The troubleshooting chart calls E3 “Thermistor Open Circuit”; the service inventory calls it “Thermistor Failure”. These labels are retained as source distinctions, not separate homeowner diagnoses.

Source: ICW manual: Error Codes and Solutions; Appliance Servicing